News

Can an MRI scan show the bone changes of spondyloarthritis like a CT does?

Can an MRI scan show the bone changes of spondyloarthritis like a CT does?

Performance of MRI-based synthetic CT for detecting spinal new bone formation in patients with inflammatory arthritis and healthy controls: a comparison with MRI, CT, and radiography

Annals of the Rheumatic Diseases 2026

Abstract

Objectives

This study aims to compare magnetic resonance imaging (MRI)–based synthetic computed tomography (sCT), T1-weighted magnetic resonance imaging (T1wMRI), low-dose CT (ldCT), and radiography for detecting spinal new bone formation (NBF) in participants with axial spondyloarthritis (axSpA), psoriatic arthritis (PsA), rheumatoid arthritis (RA) and healthy controls (HCs).

Methods

All participants underwent whole-spine ldCT and MRI in addition to cervical/lumbar spine radiography (not HCs). sCT was reconstructed using BoneMRI.Images were independently assessed for NBF by 2 readers blinded to other imaging and clinical information. One reader repeated ldCT and sCT reads after 6 months.Sensitivity and specificity were calculated using ldCT as the reference standard. Inter-reader and intra-reader reliability were assessed using intraclass correlation coefficient (ICC) and Cohen’s kappa.

Results

Sixty-nine participants (36 males, mean age 51.4 years) were included: 30 axSpA, 19 PsA, 10 RA, and 10 HCs. The mean number of NBFs per participant was 25.8 on ldCT, 24.0 on sCT, 9.3 on T1wMRI, and 6.9 on radiography. Sensitivity for NBF detection was highest for sCT (70%), followed by radiography (50% cervical/lumbar and 21% whole-spine) and T1wMRI (28%); specificity was ≥93% across modalities. Inter-reader reliability was high for sCT and ldCT (excellent ICCs, substantial kappas), whereas radiography and T1wMRI showed good ICCs with substantial/moderate kappas. Intra-reader reliability and inter-modality agreement for sCT and ldCT were excellent/substantial (ICCs/kappas).

Conclusions

Using ldCT as a reference standard, sCT demonstrated substantially higher sensitivity than T1wMRI and radiography. Intra- and inter-reader reliability and inter-modality agreement between ldCT and sCT were comparable, suggesting that discrepancies in lesion detection primarily reflect reader variability rather than inter-modality differences.

Read full study