Public source

Reviewed 8 Oct 2026

Completeness Good (42%)

MRCAT Prostate plus Auto-contouring

Philips

As a plug-in clinical application to Ingenia MR-RT, MRCAT Prostate + AutoContouring provides density information for dose calculations and accurate MRbased contours in as little as 20 minutes – all in a repeatable ‘one-click’ workflow. Because MRCAT Prostate + Auto-Contouring requires input from MR images only, it reduces the organization and coordination of scans, eliminates the effort involved in MR-CT registration, and saves the patient from undergoing multiple procedures.

No papers to support — we monitor for new evidence.

Key features

Autosegmentation

MR-only workflow

Synthetic CT Generation

General Information

Product name

MRCAT Prostate plus Auto-contouring

Company

Workflow phase

Contouring, Imaging

Modality

MR

Treatment site

Male pelvis

Exact structures

Anatomical prostate, seminal vesicles, bladder (inner and outer), rectum, penile bulb, femur head (left and right), body outline.

Regulatory Information

CE Certification

Pathway:

MDR

Class:

Class IIb

Verified by Health AI Register

Other certifications

Not specified

Evidence & Research

No research papers or evidence on file yet.

The registry monitors publications for new evidence.

Technical Specifications

Prerequisites

Specific hardware required

Defined prerequisite(s)

Ingenia 1.5T and 3.0T MR-RT, Ingenia Ambition 1.5T MR-RT and Ingenia Elition 3.0T MR-RT

Treatment technique

Not applicable

Delivery system

Not applicable

Workflow features

MR only

Patient population age

Adult

Input

MR

Input format

DICOM

Output

MRCAT images, auto-contoured structures

Output format

DICOM, DICOM RTSTRUCT

Integration

Embedded on the MR console

Integration method

Not specified

API documentation availability

Not specified

API documentation, if publicly available

Not specified

TPS compatibility

Vendor-neutral

Deployment

Not specified

Trigger for AI functionality

Not specified

Processing time

Not specified

Retraining locally

Not applicable

Claims

Duration MR-only imaging and automated prostate and OAR contouring: Within 17 minutes. Auto-Contouring calculation time: In parallel with scanning, <5 minutes

Known limitations

Not specified

Market Presence

On market since

Not specified

AI Platforms

Resellers

Not specified

Countries present

Not specified

Paying clinical customers

Not specified

Research/test users

Not specified

Pricing Information

Pricing model

Not specified

Based on

Not specified

Source: Public | First published: Apr 3, 2026 | Last updated: Oct 8, 2026